Ultra Low Pressure Reverse Osmosis RO Membrane for Water Plant

Product Details
Customization: Available
Type: Reverse Osmosis
Usage: Environmental Protection, Chemical Industry, Pure Water Production
Still deciding? Get samples of US$ 235/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
>2000 square meters
  • Ultra Low Pressure Reverse Osmosis RO Membrane for Water Plant
  • Ultra Low Pressure Reverse Osmosis RO Membrane for Water Plant
  • Ultra Low Pressure Reverse Osmosis RO Membrane for Water Plant
  • Ultra Low Pressure Reverse Osmosis RO Membrane for Water Plant
  • Ultra Low Pressure Reverse Osmosis RO Membrane for Water Plant
  • Ultra Low Pressure Reverse Osmosis RO Membrane for Water Plant
Find Similar Products

Basic Info.

Model NO.
8040-ULP
Motive Force
Pressure
Style
Tube
Performance
Efficient Filtration
Certification
CE, RoHS, ISO9001, RoHS, CE, NSF
Application
Industry
Salt Rejection Rate
99.2%
Capacity
10500 Gpd
Transport Package
1/1 Dry Film, Single Cartoon
Specification
Pure water producing
Trademark
HYNAMO
Origin
China
HS Code
8421991000
Production Capacity
300000 PCS /Month

Product Description

HN - HYNAMO Membrane
Ultra Low Pressure Reverse Osmosis RO Membrane for Water Plant
This standard provides product specifications for RO elements for industrial and similar purposes (here in after referred to as RO membrane elements).

The product specification  
Model Number Description 8040-ULP
Performance &
Test Condition
The Desalination Rate % 99.2%
Water Rate GDP 10500
The Test pressure 150psi
Test solution Temperature 25± 1ºC
Test Solution Concentration (1:1:1) labeling 1500ppm
Test solution PH value 6.5-7.5
Recovery Of Single-Branch Membrane Element 15%
 
Feed water SDI 5

Operating Limit:
Maximum Operating Temperature 113ºF(45ºC)
Maximum Working Pressure 600psi(41.0 bar)
The high pressure drop 15psi (1.0bar)
Continuously operating PH range a 3-10
Short wash PH range (30min) b 2-12
Maximum feed water SDI SDI 5
Tolerance Of Free Chlorine <0.1ppm
Maximum pressure drop for single membrane element 15psi(0.1Mpa)
  1.  When PH is above 10, the Maximum Temperature of Continuous Operation is 35ºC.
  2. Under certain conditions, the presence of free chlorine and other oxidants in the water may cause serious membrane damage, which doesn't belong to product warranty range.
Ultra Low Pressure Reverse Osmosis RO Membrane for Water Plant
Ultra Low Pressure Reverse Osmosis RO Membrane for Water Plant
Ultra Low Pressure Reverse Osmosis RO Membrane for Water Plant
Ultra Low Pressure Reverse Osmosis RO Membrane for Water Plant

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier