Customization: | Available |
---|---|
After-sales Service: | Provided |
Warranty: | 1 Year Warranty |
Still deciding? Get samples of US$ 235/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
TYPE | Production Flow Rate GPD(m³/d) | Stable Rejection Rate | Operation Pressure | Recovery Rate |
4040-LP | 2400(9.1) | 99.5% | 225 psi (15bar) | 15% |
4040-ULP | 2400(9.1) | 99.2% | 150 psi (10bar) | 15% |
4040-XLP | 2400(9.1) | 98.5% | 100 psi (7bar) | 15% |
8040-LP | 10500(40) | 99.5% | 225 psi (15bar) | 15% |
8040-ULP | 10500(40) | 99.2% | 150 psi (10bar) | 15% |
8040-XLP | 10500(40) | 98.5% | 100 psi (7bar) | 15% |
LP(Low Pressure) | ULP(Ultra Low Pressure) | XLP(Extra Low Pressure) | |
Test Conditions | 2000 ppm Nacl Solution 225 psi Applied Pressure 77F (25ºC)Operation Temperature 15% Pemeate Recovery 6.5-7.5 PH Range |
1500 ppm Nacl Solution 150 psi Applied Pressure 77F (25ºC)Operation Temperature 15% Pemeate Recovery 6.5-7.5 PH Range |
1500 ppm Nacl Solution 100 psi Applied Pressure 77F (25ºC)Operation Temperature 15% Pemeate Recovery 6.5-7.5 PH Range |
Type | Configuration: Low Pressure Spiral Membrane Polymer: Composite polyamide Membrane O Ring: EPDM |
Maximum Operating Temperature | 113ºF(45ºC) |
Maximum Working Pressure | 600psi(41.0 bar) |
The high pressure drop | 15psi (1.0bar) |
Continuously operating PH range a | 3-10 |
Short wash PH range (30min) b | 2-12 |
Maximum feed water SDI | SDI 5 |
Tolerance Of Free Chlorine | <0.1ppm |
Maximum pressure drop for single membrane element | 15psi(0.1Mpa) |
Model | GT-3313-800 |
Operation Pressure (psi) | 100 |
Highest Operation Pressure (psi) | 150 |
Application | For Pure water producing |
Test Solution Concentration NaCl (ppm) | 250±50ppm |
Recovery Rate % | 50%±5 |
Stable Rejection Rate % | 95 |
Flow Rate (GPD) | 800 |
Max. Pressure Difference (psi) | 15 |
Max. Feed Water SDI | 5 |
Acceptance capacity of free Chlorine | ≤0.1 |
PH Range of feed water as continious operation | 2-11 |
model |
Stable rejection rate(%) |
average permeate flowGPD(m3/d ) |
test condition |
||
operation pressure psi(Mpa) | test liquid NaCl(ppm) |
recovery rate (%) |
|||
1812-BW50 | 97 | 50(0.19) | 60(0.41) | 250 | 15 |
1812-BW75 | 97 | 75(0.28) | 60(0.41) | 250 | 15 |
1812-BW100 | 97 | 100(0.38) | 60(0.41) | 250 | 15 |
2012-150 | 95 | 150(0.57) | 70(0.5) | 500 | 15 |
2012-200 | 95 | 200(0.76) | 70(0.5) | 500 | 15 |
2812-300 | 97 | 300(1.14) | 70(0.5) | 500 | 15 |
2812-400 | 95 | 400(1.52) | 70(0.5) | 500 | 15 |
3012-600 | 95 | 600(2.28) | 90(0.62) | 250 | 50 |
3012-800 | 95 | 800(3.04) | 100(0.68) | 250 | 50 |
3013-400 | 95 | 400(1.52) | 70(0.5) | 500 | 15 |
3013-600 | 95 | 600(2.28) | 70(0.5) | 500 | 15 |
3013-800 | 95 | 800(3.04) | 100(0.68) | 500 | 15 |
4040-XLP | 98.5 | 2400(9.12) | 100(0.68) | 500 | 15 |
4040-ULP | 99.2 | 2400(9.12) | 150(1.02) | 1500 | 15 |
4040-LP | 99.5 | 2400(9.12) | 225(1.53) | 2000 | 15 |
8040-XLP | 98.5 | 10500(39.9) | 100(0.68) | 500 | 15 |
8040-ULP | 99.2 | 10500(39.9) | 150(1.02) | 1500 | 15 |
8040-LP | 99.5 | 10500(39.9) | 225(1.53) | 2000 | 15 |