• UF NF RO Membrane for Wastewater Treatment Systems Household 2012-75 Gpd
  • UF NF RO Membrane for Wastewater Treatment Systems Household 2012-75 Gpd
  • UF NF RO Membrane for Wastewater Treatment Systems Household 2012-75 Gpd
  • UF NF RO Membrane for Wastewater Treatment Systems Household 2012-75 Gpd
  • UF NF RO Membrane for Wastewater Treatment Systems Household 2012-75 Gpd
  • UF NF RO Membrane for Wastewater Treatment Systems Household 2012-75 Gpd

UF NF RO Membrane for Wastewater Treatment Systems Household 2012-75 Gpd

Certification: ISO9001, RoHS, CE, NSF
Salt Rejection Rate: 97%
Application: Household
Capacity: 75 Gallon
Warranty: 1 Year
Working up: 1000TDS
Samples:
US$ 3/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2019

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
BW-2012-75
Operation Pressure
65psi
Max Adapted Temperature
113f(45ºC)
Transport Package
Carton Box
Specification
polyamide
Trademark
HYNAMO, OEM or ODM
Origin
Hangzhou
HS Code
8421991000
Production Capacity
20000PCS/Day

Product Description


Introduction

HN-JCM brand membrane element produced by world advanced membrane technology and fully automatic production equipment. It can operation under the extra low pressure. Our membrane suitable for household water purifiers, hospitals, laboratory pure water, treatment  municipal tap water, well water and other low salinity water sources.
UF NF RO Membrane for Wastewater Treatment Systems Household 2012-75 Gpd
Advantages of our household reverse osmosis membrane: 

1. It should have high-efficiency desalination rate at high flow rate. 

2. It has high mechanical strength and service life. 

3. Can function under lower operating pressure. 

4. Good chemical stability and high cost performance.



Performance
TYPE BW-1812-50 BW-2012-75 BW-2012-100 BW-2012-150
Rejection Rate 97% 97% 97% 96%
Permeate Flow GPD(m³) 50(0.19) 75(0.28) 100(0.38) 150(0.57)
Test Pressure 60psi(0.41MPa) 70psi(0.5MPa)
Max. Feedwater TDS 1000
PH Rate Rang of Operation 3-10
Max. Operation Temperature 45ºC
Recovery Rate of Single Membrane 15%

Note:1. The Max. continous operation temperature is 35ºC when PH rate over 10.
         2.In certain conditions,if would cause membrane breakage if the free chlorine or the other oxidant in feedwater.The production quality guarantee range is notincluded membrane breakage by oxiadation.


Membrane Dimentions
UF NF RO Membrane for Wastewater Treatment Systems Household 2012-75 Gpd
 
Model No. A(Inch/mm) B(Inch/mm) C(Inch/mm) D(Inch/mm) E(Inch/mm)
BW-1812-50 11.74/298 1.70/44 0.68/17 0.87/22 10.0/254
BW-2012-75 11.74/298  1.75/45.5 0.68/17 0.87/22 10.0/254
BW-2012-100 11.74/298   1.8/46.5 0.68/17 0.87/22 10.0/254
BW-2012-150 11.74/298  1.9/48 0.68/17 0.87/22 10.0/254


ABOUT US
HYNAMO, Established since 2005.
Hangzhou Haina Environmental Protection Technology Co., Ltd.

We specialize in the development and manufacture of Reverse Osmosis Products.
We are composed of a team with rich experience engnieers and professional R & D personnel.
We insist on learning the most cutting-edge technology and provide high-quality products to customers.
UF NF RO Membrane for Wastewater Treatment Systems Household 2012-75 Gpd
UF NF RO Membrane for Wastewater Treatment Systems Household 2012-75 Gpd
UF NF RO Membrane for Wastewater Treatment Systems Household 2012-75 Gpd
UF NF RO Membrane for Wastewater Treatment Systems Household 2012-75 Gpd
UF NF RO Membrane for Wastewater Treatment Systems Household 2012-75 Gpd

Our Exhibitions
UF NF RO Membrane for Wastewater Treatment Systems Household 2012-75 Gpd
UF NF RO Membrane for Wastewater Treatment Systems Household 2012-75 Gpd


Certifications
UF NF RO Membrane for Wastewater Treatment Systems Household 2012-75 Gpd
UF NF RO Membrane for Wastewater Treatment Systems Household 2012-75 Gpd
FAQ:

1. Q: Are you a trading company or a manufacturer?

A: We are a professional manufacturer of RO membrane and membrane sheet with 18 years experience in the industry.

2. Q: May I have samples?

A: Sure,of course. Sample cost can be refunded if you place formal orders in the future.

3. Q: Can you make customized products?

A: Yes,of course if you can provide us detailed specifications or drawings. Our mission is make customer idea on the products and provide the customer satisfied solutions.

4. Q: Can I use our own designed package?

A: Yes, size, color, logo and packaging style all can be customized.

5. Q: What's your MOQ?

A: Normally, 50 PCS/item for Industrial RO membrane, 100 PCS/item for domestic. Any trial order which is less than MOQ is warmly welcomed. If you have a trialorder, please feel free to contact us so that we can make some shipping recommendation for you to save the cost based on the quantity you need.

6. Q: I am a small business owner, Can I buy from you?

A: Yes, you are warmly welcomed. To grow with our customer is our goal.We would like to grow with you together.

7. Q: What is your general lead time?

A: Normally 3-7working days for off-the-shelf samples and 14-25 days for bulk production.



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.